Risk-Aware Robust Learning: Reducing Clinical Risk under Label Noise in Medical Image Classification

📅 2026-04-26
📈 Citations: 0
Influential: 0
📄 PDF
🤖 AI Summary
This study addresses the critical yet often overlooked issue of annotation noise in medical image classification, where conventional noise-robust methods prioritize overall accuracy while neglecting the severe clinical consequences of high-risk misdiagnoses such as false negatives. For the first time, it systematically evaluates prominent robust learning approaches—including Co-teaching, DivideMix, UNICON, and GMM filtering—from a clinical safety perspective on DermaMNIST and PathMNIST benchmarks. The work proposes integrating cost-sensitive optimization into noise-robust training by incorporating a global risk metric that imposes substantially higher penalties on false negatives. Experimental results demonstrate that existing methods fail to ensure clinical safety, whereas the proposed paradigm effectively reduces high-risk diagnostic errors without compromising overall model performance.

Technology Category

Application Category

📝 Abstract
Noisy labels are a pervasive challenge in medical image classification, where annotation errors arise from inter-observer variability and diagnostic ambiguity. Although several noise-robust learning methods have been proposed, their evaluation predominantly relies on accuracy-oriented metrics, overlooking the clinical implications of asymmetric error costs. In medical diagnosis, a false negative (missed disease) carries substantially higher consequences than a false positive (false alarm), as delayed treatment can directly impact patient outcomes. In this work, we investigate whether noise-robust training methods preserve clinical safety under label noise. We conduct a systematic risk-aware evaluation of the state-of-the-art noise-robust methods Coteaching, DivideMix, UNICON, and a GMM-based filtering approach on binarized DermaMNIST and PathMNIST datasets under clean and label noise rates of 20%, and 40%. Beyond balanced accuracy, we adopt a cost-sensitive Global Risk formulation that explicitly penalizes false negatives. Our analysis reveals that the robustness of state-of-the-art methods does not guarantee clinical safety. Furthermore, we demonstrate that integrating cost-sensitive optimization into noise-robust training significantly reduces clinical risk, while mantaining model utility. These findings demonstrate that noise-robust learning must be evaluated through a clinical risk lens, and that combining robust training with cost-sensitive optimization can meaningfully reduce risk in noisy-label medical imaging scenarios.
Problem

Research questions and friction points this paper is trying to address.

label noise
medical image classification
clinical risk
false negative
cost-sensitive learning
Innovation

Methods, ideas, or system contributions that make the work stand out.

risk-aware learning
label noise
cost-sensitive optimization
medical image classification
clinical safety
🔎 Similar Papers
No similar papers found.
💼 Related Jobs
No related jobs found.
M
Maycon R. S. Pereira
Visual Computing Lab, Departamento de Computação, Universidade Federal Rural de Pernambuco (UFRPE), Brasil
Filipe R. Cordeiro
Filipe R. Cordeiro
Universidade Federal Rural de Pernambuco
Machine LearningComputer VisionMedical Image Analysis