MRI-Guided Reslice-Refined Cross-Slice SDF Reconstruction of the Left Ventricle from Cardiac MRI with Sparse Axial Supervision

📅 2026-09-08
📈 Citations: 0
Influential: 0
📄 PDF
🤖 AI Summary
本文提出了一种基于稀疏轴向监督的心脏MRI数据重建左心室三维内膜表面的方法,通过结合多角度几何线索和图像边界信息来优化隐式符号距离场。
📝 Abstract
Reconstructing a three-dimensional left-ventricular (LV) endocardial surface from cardiac magnetic resonance (CMR) data is challenging when supervision is available on only a small number of axial slices. Through-plane geometry is weakly constrained, and automatically generated two-dimensional masks can propagate segmentation errors into the recovered shape. We present MR-RS-SDFR, a per-case implicit signed distance field (SDF) framework that reconstructs a continuous LV surface from a CMR volume and sparse axial weak masks. The method first builds a cross-slice SDF initialization from axial and longitudinal geometric cues and then refines the field using two complementary signals: MRI edge-field normal alignment, which provides an image-derived boundary cue independent of the weak masks, and differentiable reslice Dice and contour consistency, which preserve agreement with the observed planes. We evaluate three weak-mask generators -- LOO TransUNet, LOO nnU-Net, and an off-the-shelf Medical SAM3 model used without MM-WHS-specific training or fine-tuning -- and five sparsity levels from 4 to 64 axial planes. In the sparse-16 setting, final MR-RS-SDFR reconstruction reaches 0.928 Dice and 3.80mm HD95 with Medical SAM3 masks. The upstream generators do not exhibit a single common ranking across 2D and dense 3D segmentation, and nnU-Net- and Medical-SAM3-driven sparse reconstruction achieve the same mean final Dice despite different upstream error profiles. Across all three sparse-16 mask sources, MR-RS-SDFR is numerically better than protocol-matched full GHD+DVS in both Dice and HD95. Final Dice improves markedly from sparse-4 to sparse-16 and then saturates at the reported precision through sparse-64. These results support MRI-guided per-case SDF refinement as a reconstruction strategy that remains effective across weak-mask generators and supervision densities.
Problem

Research questions and friction points this paper is trying to address.

MRI
Left Ventricle
Sparse Supervision
SDF Reconstruction
Cardiac MRI
Innovation

Methods, ideas, or system contributions that make the work stand out.

MRI-guided
SDF refinement
sparse axial supervision
cross-slice SDF initialization
differentiable reslice Dice and contour consistency
💼 Related Jobs
No related jobs found.
Q
Quanxin Zheng
China Electronics (Beijing) Information Technology Research Institute Co., Ltd.
Shuai Zhao
Shuai Zhao
Beijing Institute of Technology
SSL LLM